6 research outputs found

    Population-based colorectal cancer screening programmes using a faecal immunochemical test:Should faecal haemoglobin cut-offs differ by age and sex?

    Get PDF
    Abstract Background The Basque Colorectal Cancer Screening Programme has both high participation rate and high compliance rate of colonoscopy after a positive faecal occult blood test (FIT). Although, colorectal cancer (CRC) screening with biannual (FIT) has shown to reduce CRC mortality, the ultimate effectiveness of the screening programmes depends on the accuracy of FIT and post-FIT colonoscopy, and thus, harms related to false results might not be underestimated. Current CRC screening programmes use a single faecal haemoglobin concentration (f-Hb) cut-off for colonoscopy referral for both sexes and all ages. We aimed to determine optimum f-Hb cut-offs by sex and age without compromising neoplasia detection and interval cancer proportion. Methods Prospective cohort study using a single-sample faecal immunochemical test (FIT) on 444,582 invited average-risk subjects aged 50–69 years. A result was considered positive at ≥20 μg Hb/g faeces. Outcome measures were analysed by sex and age for a wide range of f-Hb cut-offs. Results We analysed 17,387 positive participants in the programme who underwent colonoscopy. Participation rate was 66.5%. Men had a positivity rate for f-Hb of 8.3% and women 4.8% (p < 0.0001). The detection rate for advanced neoplasia (cancer plus advanced adenoma) was 44.0‰ for men and 15.9‰ for women (p < 0.0001). The number of colonoscopies required decreased in both sexes and all age groups through increasing the f-Hb cut-off. However, the loss in CRC detection increased by up to 28.1% in men and 22.9% in women. CRC missed were generally at early stages (Stage I-II: from 70.2% in men to 66.3% in women). Conclusions This study provides detailed outcomes in men and women of different ages at a range of f-Hb cut-offs. We found differences in positivity rates, neoplasia detection rate, number needed to screen, and interval cancers in men and women and in younger and older groups. However, there are factors other than sex and age to consider when consideration is given to setting the f-Hb cut-off

    Measurement of the Higgs boson production rate in association with top quarks in final states with electrons, muons, and hadronically decaying tau leptons at s√=13TeV

    Get PDF
    The rate for Higgs (H) bosons production in association with either one (tH) or two (tt¯H) top quarks is measured in final states containing multiple electrons, muons, or tau leptons decaying to hadrons and a neutrino, using proton–proton collisions recorded at a center-of-mass energy of 13TeV by the CMS experiment. The analyzed data correspond to an integrated luminosity of 137fb−1. The analysis is aimed at events that contain H→WW, H→ττ, or H→ZZ decays and each of the top quark(s) decays either to lepton+jets or all-jet channels. Sensitivity to signal is maximized by including ten signatures in the analysis, depending on the lepton multiplicity. The separation among tH, tt¯H, and the backgrounds is enhanced through machine-learning techniques and matrix-element methods. The measured production rates for the tt¯H and tH signals correspond to 0.92±0.19(stat)+0.17−0.13(syst) and 5.7±2.7(stat)±3.0(syst) of their respective standard model (SM) expectations. The corresponding observed (expected) significance amounts to 4.7 (5.2) standard deviations for tt¯H, and to 1.4 (0.3) for tH production. Assuming that the Higgs boson coupling to the tau lepton is equal in strength to its expectation in the SM, the coupling yt of the Higgs boson to the top quark divided by its SM expectation, κt=yt/ySMt, is constrained to be within −0.9<κt<−0.7 or 0.7<κt<1.1, at 95% confidence level. This result is the most sensitive measurement of the tt¯H production rate to date.SCOAP

    Immune Response to Natural and Experimental Infection of Panulirus argus Virus 1 (PaV1) in Juveniles of Caribbean Spiny Lobster

    No full text
    Experimental infections have been used to better comprehend the immune system of organisms, and to probe for additives that generate greater resistance and help reduce antibiotic use in aquaculture. We compared the immune response of juveniles of the Caribbean spiny lobster, Panulirus argus, infected naturally with Panulirus argus virus 1 (PaV1) versus organisms infected experimentally, to determine the analogy between both infectious processes. The immunological response was measured by hemagglutination activity, hemocyte count, and total phenoloxidase activity in plasma and hemocytes in 211 individuals that were either naturally infected (110), or had been injected with viral inoculum and followed for six months (101). The samples were classified into the following four groups according to the severity of the infection: 0, uninfected; 1, lightly; 2, moderately; and 3, severely infected), which was determined on the basis of PCR and histological criteria. A permutational MANOVA showed that both the origin (natural and experimental), and the severity of the infection contributed significantly to explain the variation in the immune response of lobsters. The lack of significance of the interaction term indicated that the immunological response changed with the severity of the infection in a similar way, regardless of its origin. The results of the present study suggest that the experimental viral infection of PaV1 produces a defense response similar to the natural pathways of contagion, and provides the bases to validate an immunological challenge protocol for the first time in crustaceans. The discussion includes the perspective of the conceptual models of immune response within an ecological context

    Erratum to: Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition) (Autophagy, 12, 1, 1-222, 10.1080/15548627.2015.1100356

    No full text
    non present

    Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition)

    No full text
    corecore